Infinity
INFINITY EVO 3100 - 3300
INFINITY EVO comes in version 3100 with single-phase output in ratings of 10-15-20kVAand version 3300 with three-phase output in ratings from 10 to 40kVA. It is the only model in our range that is transformerless and, for this reason, particularly suitable to supply Data Centre and Telecom installations. The logic includes two 32-bit microprocessors which enable a very precise control system for all the equipment parameters, including those relevant to the direct current that could spread to the loads due to the lack of an output transformer. This product line also has the plug and play parallel characteristic: due to a sophisticated algorithm designed by our research and development team, the current -sharing optimizes efficiency, thereby reducing operating costs. Easy access to the sub -systems composing the Infinity makes functional on-site tests extremely fast and reduces maintenance time (MTIR). This UPS has the characteristic of being compact in size (only 45 cm wide): it is a small jewel of technology mounted on casters.
Nominal output power (0.8 PF)- kVA | 10 | 15 | 20 |
---|---|---|---|
Nominal input voltage • Vac | 400 ( -20%/ +15%); 380/415 settabile | ||
Nominal input current - A | 12 | 19 | 23 |
Input power factor | >0.99 | ||
Input harmonics distortion (THOI) | <4% | ||
Nominal output voltage • Vac | 220 • 230 • 240 (+/-0.5%) | ||
Output frequency· Hz |
50/60 | ||
Efficiency (AC+AC) • % eco mode | upto 99 | ||
Efficiency (AC+AC) • % | upto 94 | ||
UPSambient temperature -c· | 0-40 | ||
Audible noise level (ace En50091) -dB | <52 | ||
Battery test | Automatic every month/ manual | ||
Rectifier bridge | IGBT | ||
Inverter bridge | IGBT(high efficiency transformerless) | ||
Overload capability | 125%for10',150%for1', 200%for 100ms | ||
Output harmonic distortion (THDV) | <2% | ||
Crest factor | 3:1 | ||
Dimensions WxDxH • mm | 450 X 670 X 1200 | ||
Walk-in | Adjustable from5" to 30" | ||
Hold-off | Adjustable from l" to 300" |
Nominal output power (0.8 PF) - kVA | 10 | 15 | 20 | 30 | 40 |
---|---|---|---|---|---|
Nominal input voltage • Vac | 400 ( -20% / +15%); 380/415 settabile | ||||
Nominal input current • A | 12 | 19 | 23 | 38 | 50 |
In put power factor | >0.99 | ||||
Input harmonics distortion (THOI) | <4% | ||||
Nominal output voltage • Vac | 380 • 400 • 415 (+/-0.5%) | ||||
Output frequency · Hz |
50/60 | ||||
Efficiency (AC+AC) • % eco mode | up to 99 | ||||
Efficiency (AC+AC) - % | up to 94 | ||||
UPS ambient temper ature -c· | 0 - 40 | ||||
Audible noise level (acc. En50091) - dB | <52 | ||||
Battery test | Automatic every month/ manual | ||||
Rectifier bridge | IGBT | ||||
Inverter bridge | IGBT (high efficiency transformerless) | ||||
Overload capability | 125%per 10min.,125%+150% per30sec., >150%per10 sec. | ||||
Output harmonic distorti on (THOV) | <1% | ||||
Crest factor | 3:1 | ||||
Dimensions WxOxH • mm | 450 X 670 X 1200 | ||||
Walk- in | Adjustable from5" to 30" | ||||
Hold-off | Adjustable from 1" to 300" |